<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-17 06-40-01
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.30 MHz 5/5, 76 dBuV NOSTALGI
Pilot RDS Phase Difference
6.0 kHz 3.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 69 kHz 19100 0,0157
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,3 dBr 5,72 dBr 7,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"NOSTALGI" 6411 10 (Pop M) 1 0 1 7 --:--
RT
"Elamasi musiikkia. "
AF EON
92.7, 94.3, 99.5, 100.5 MHz -
FM Scope Max at: 69 kHz MIN: 11 kHz % above 76 kHz: 0,0157 Acquired: 2025/02/17 6.38.58 Total samples: 19100 Equivalent time: 0:15:55 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 7,4 dBr MIN: 4,3 dBr AVE: 5,72 dBr % above 12,2 dBr: 0,0 Last value: 5,9 dBr (2025/02/17 6.38.57) 06.26 06.28 06.30 06.32 06.34 06.36 06.38 0 2 4 6 8 Pm [dBr]